GUC_check_errdetail("List syntax is invalid.");
}
- else if (!ReplicationSlotCtl)
+ else if (MyProc)
{
/*
- * We cannot validate the replication slot if the replication slots'
- * data has not been initialized. This is ok as we will anyway
- * validate the specified slot when waiting for them to catch up. See
- * StandbySlotsHaveCaughtup() for details.
+ * Check that each specified slot exist and is physical.
+ *
+ * Because we need an LWLock, we cannot do this on processes without a
+ * PGPROC, so we skip it there; but see comments in
+ * StandbySlotsHaveCaughtup() as to why that's not a problem.
*/
- }
- else
- {
- /* Check that the specified slots exist and are logical slots */
LWLockAcquire(ReplicationSlotControlLock, LW_SHARED);
foreach_ptr(char, name, *elemlist)
slot = SearchNamedReplicationSlot(name, false);
+ /*
+ * If a slot name provided in synchronized_standby_slots does not
+ * exist, report a message and exit the loop.
+ *
+ * Though validate_sync_standby_slots (the GUC check_hook) tries to
+ * avoid this, it can nonetheless happen because the user can specify
+ * a nonexistent slot name before server startup. That function cannot
+ * validate such a slot during startup, as ReplicationSlotCtl is not
+ * initialized by then. Also, the user might have dropped one slot.
+ */
if (!slot)
{
- /*
- * If a slot name provided in synchronized_standby_slots does not
- * exist, report a message and exit the loop. A user can specify a
- * slot name that does not exist just before the server startup.
- * The GUC check_hook(validate_sync_standby_slots) cannot validate
- * such a slot during startup as the ReplicationSlotCtl shared
- * memory is not initialized at that time. It is also possible for
- * a user to drop the slot in synchronized_standby_slots
- * afterwards.
- */
ereport(elevel,
errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("replication slot \"%s\" specified in parameter \"%s\" does not exist",
break;
}
+ /* Same as above: if a slot is not physical, exit the loop. */
if (SlotIsLogical(slot))
{
- /*
- * If a logical slot name is provided in
- * synchronized_standby_slots, report a message and exit the loop.
- * Similar to the non-existent case, a user can specify a logical
- * slot name in synchronized_standby_slots before the server
- * startup, or drop an existing physical slot and recreate a
- * logical slot with the same name.
- */
ereport(elevel,
errcode(ERRCODE_INVALID_PARAMETER_VALUE),
errmsg("cannot specify logical replication slot \"%s\" in parameter \"%s\"",